Customization: | Available |
---|---|
Cooling Method: | Air Cooling |
Frequency Band: | Low Frequency |
Still deciding? Get samples of US$ 600/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Item | Model | ||||||
LGK-63IGBT | LGK-100IGBT | LGK-120IGBT | LGK-160IGBT | LGK-200IGBT | LGK-300IGBT | LGK-400IGBT | |
Input source (V/Hz) | 3-380±15% 50/60 | ||||||
Rated input capacity (KVA) | 9.5 | 17.8 | 22.4 | 32.2 | 46.7 | 65.8 | 94.1 |
Rated input current (A) | 14.5 | 27 | 34 | 49 | 71 | 100 | 143 |
Rated output current (A) | 63 | 100 | 120 | 160 | 200 | 300 | 400 |
Rated output voltage (v) | 106 | 120 | 128 | 144 | 160 | 200 | 200 |
Rated unloading voltage (v) | 300 | 300 | 300 | 315 | 315 | 380 | 380 |
Rated loading cycle | 60%(40ºC) | 100%(40ºC) | |||||
Range of output current (A | 30-63 | 30-100 | 30-120 | 30-160 | 30-200 | 30-300 | 30-400 |
Ratio of arc pressure output signal | 1:1/1:20/1:50/1:100 | 1:1/1:20 | |||||
Qualified cutting capacity (carbon steel) (mm) | 0.3-12 | 0.3-22 | 0.3-25 | 0.3-35 | 0.3-45 | 0.3-50 | 0.3-60 |
Cutting capacity (carbon steel) (mm) | 25 | 40 | 45 | 55 | 65 | 80 | 90 |
Plasma air | Air compressor | ||||||
Air pressure (mpa) | 0.3-0.5 | 0.4-0.6 | 0.45-0.6 | ||||
Cooling method of torch | Air cooling | Air cooling/Water cooling | |||||
Cooling method of source | Air cooling | ||||||
Insulation grade | Grade F | ||||||
Shell protect grade | IP21S | ||||||
Dimension (mm) | 585*280*485 | 675*320*605 | 800*380*650 | 800*380*810 | 890*430*900 | 930*430*900 | |
Net weight (kg) | 26 | 45 | 46 | 65 | 82 | 124 | 144 |